WATERQUBE SYSTEM MAINTAINENCE
Filter Bags are replaced based on increasing pressure between water harvest pump and filter bags. This increase
in pressure indicates the bag are progressively blocking
from the collection of sediment from the water source. The frequency of bag changes will be dependent on the quality of the water source and the filtration of the bags selected (50um, 25um, 5um, 1um). The Filter Bag Pressure will be measured and monitored by the Water Harvest Pump Controller.
Activated Carbon will not block but will eventually fail to absorb the natural organic compounds present in the water source. This can be detected by water quality measurement of the Activated Carbon can be replaced at set, periodic intervals. The Activated Carbon is replaced by removing the canisters, opening and replacing the contents.
NanomeshTM are nominally rated at 60,000 litres capacity but will last for longer with effective Primary Filtration. The Nanomesh is installed in a bank of five parallel units and assuming full daily use of the WateQube, should be replaced monthly by swapping Nanomesh cartridges.